Can You DIY Air Duct Installation? (When to Call a Pro in Palm Beach County)
- Adam Haas

- Oct 21
- 9 min read
DIY is realistic for:
Adding or upsizing a return in an accessible attic.
Fixing one “hot room” by improving supply size/route, sealing leaks, and balancing.
Sealing and insulating existing ducts, replacing grilles/boots, and adding dampers.
You need load/duct redesign across multiple rooms, or your static pressure is already high (you’ll measure this shortly).
You’re modifying the main trunk or plenum, relocating equipment, or routing through tight/low‑clearance attics where safety is sketchy.
You suspect hazardous materials, or you’re unsure about permits (Palm Beach County and the Village of Wellington may require them for new runs or significant alterations).
You want design docs (Manual J/S/D) and warrantied workmanship.
Quick way to vet a pro: Ask for before/after static pressure, room‑by‑room CFM targets, and a sketch of the new return/supply paths. If they can’t provide those, keep calling.
Ductwork Basics: Supply vs. Return, Materials, and What Works in Humid Florida Attics

Supply pushes conditioned air into rooms; return pulls air back to the air handler. South Florida homes often benefit from generous returns to reduce pressure imbalances and improve dehumidification.
Materials:
Metal (galvanized/aluminum): Best for plenums, trunks, takeoffs, and areas you want durable, quiet airflow. It’s what I use for “anchor” parts.
Flex (R‑8 for attic): Fine for short, straight runs; avoid long, saggy routing. Keep it pulled tight, supported every 4 ft (or better), and avoid sharp bends.
Sealants: UL‑181 mastic (primary) and UL‑181 tape (for outer jacket only).
Insulation: In Palm Beach attics, R‑8 is typical for supply/return runs in unconditioned space to reduce condensation risk.
Quiet & comfort tip: Larger ducts at lower face velocity are quieter and dehumidify better than undersized, high‑velocity runs that hiss and short‑cycle.
Plan Before You Cut: Manual J/S/D Made Simple for Beginners
You don’t need full software to make good, safe choices—you just need targets and checks.
Room target (Manual J‑lite):
Your 300 sq ft room target is ~300 CFM (a practical starting point you supplied).
If the room still runs hot after you hit 300 CFM, look at infiltration, solar gain, and return path before throwing more supply at it.
Duct sizing (Manual D‑lite):
Rough, real‑world rules of thumb many techs use: 6" round flex often carries ~100 CFM, 8" ~200 CFM, 10" ~300–400 CFM when installed correctly and static pressure allows.
For a 300 CFM target, you’re typically looking at one 10" supply to the room or two 6–8" supplies splitting the load. Keep runs short and straight.
Equipment limits (Manual S‑lite):
Check your air handler’s nameplate and documentation for allowable total external static pressure (TESP). A common target is around 0.5 in. w.c., but use the manufacturer’s spec. You’ll test this later.
Room‑by‑Room CFM Example (Applying It to a 300 sq ft Hot Room)
Target: 300 CFM.
Register approach: Two 8"x10" supply grilles or one larger grille can deliver 300 CFM at comfortable velocities.
Return path: Add one dedicated return or a jump duct to the hallway if the door shuts and the room pressurizes. If doors slam or the room whistles, that’s a return problem, not just supply.
Trunk, Branch, and Return Design 101
Branches should leave the trunk at a smooth angle (prefer wyes over hard 90s).
Returns need low restriction and quiet routing; keep them away from kitchens/garage.
Never rely on door undercuts alone for bedrooms in tight homes—give air a real path back.
Permits, Codes & R‑Values in Palm Beach County (Non‑Legal Guidance + Where to Verify)
Permits: Modifying ductwork, especially adding new runs, cutting into the plenum, or changing the return architecture, can trigger a mechanical permit. Verify with Palm Beach County or Wellington permit offices.
Inspection touchpoints: Duct support spacing, sealing methods (UL‑181), insulation R‑value (R‑8 in attics), and fire/thermal barriers around the air handler or where ducts pass near combustion appliances.
Documentation to keep: A simple plan sketch, materials list, photos of sealing and supports, and before/after static pressure notes.
If permits or inspections make you uneasy, hire a Florida‑licensed HVAC contractor (Class A/B, “CAC” license) to pull permits and close out inspections.
Tools & Materials Checklist (Metal vs. Flex, UL‑181, Hangers, Insulation)
Core tools I used: snips, crimper, stapler, strap, drill/driver, hole saw or manual collar cutter, manometer, anemometer, smoke pen, headlamp, PPE (gloves, eye protection, respirator), kneeboards.
Materials that cover most projects:
Metal parts: plenum takeoffs/starting collars, wyes, elbows, balancing dampers, boots, transition fittings.
Flex: R‑8 supply/return duct (keep runs short and tight).
Sealing: Mastic (primary), UL‑181 tape (jacket), mesh tape for big gaps.
Supports: nylon/metal straps, long screws, saddles as needed.
Grilles/registers: quiet, larger‑face models for bedrooms; return grilles with adequate free area.
Firestop/penetration materials where required; caulk to seal boots to drywall.
What I Used and Why (Snips, Crimper, Manometer, Anemometer, Smoke Pen)
Manometer: to check TESP and confirm I didn’t choke the system after adding a return.
Anemometer: to estimate register CFM (face velocity × grille free area).
Smoke pen: to find leaks and verify return pulls air from the room, not the attic.
Site Prep & Safety in Tight, Hot Attics (Pests, PPE, and Heat Protocols)
Work early/late, hydrate, and lay kneeboards/plywood for safe access.
Locate electrical and avoid step‑throughs (mark joists).
Pests: I once opened a Delray Beach attic and found a raccoon staring like a foreman. When I started driving a collar into a joist, he panicked and scattered my screws and even flipped my soda. I backed out, called animal control, and only then finished. Lesson: check for critters first—don’t try to “shoo” them out in a cramped attic.
PPE: Gloves, eye protection, and a respirator when cutting or working around insulation.
Clear the path: Pre‑hang straps, pre‑fit collars, and stage all parts to limit time in the heat.

Step‑by‑Step: Adding or Upsizing Return Air Vents
Pick the location: Central to the room or hallway; avoid noise‑sensitive walls.
Size the grille: Choose ample free area; bigger is quieter.
Cut the boot opening and attach the boot securely.
Run the return duct: Keep it short/straight back to the return plenum; support every ~4 ft, avoid kinks.
Install a balancing damper near the trunk if needed for future tuning.
Collar the plenum: Cut the hole cleanly, install the starter collar with screws, and mastic everything (collar lip, seams).
Seal boots to drywall with caulk/foam and tape the outer jacket.
Test: With the door closed, the room shouldn’t pressurize—use the smoke pen at the undercut to verify flow direction.
Cut & Collar the Plenum, Seal, Strap, and Support
Use a template for the collar, pilot hole, then a circle/offset cut.
Three screws minimum per collar tab; mastic liberally.
Strap the duct so it runs like a straight line—not a hammock.
Return Placement to Calm Noisy Doors & Improve Circulation
If doors slam or whistle, the house is pressure‑imbalanced. Adding a bedroom return or jump duct (bedroom → hall) relieves pressure and quiets the space.
Step‑by‑Step: Fixing Hot Rooms Without Replacing All Ducts
Measure current airflow at the room’s register(s) using the anemometer.
Choose the strategy:
Upsize the existing branch or
Add a second branch (often cleaner and quieter).
Shorten and straighten the run; reduce elbows/kinks.
Upgrade the register to a larger, quiet model.
Seal all joints and insulate.
Add a balancing damper at the takeoff so you can allocate more air to this room.
Re‑test and adjust.
Duct Sizing & Register Upgrades
For ~300 CFM, think one 10" supply or two 6–8" supplies.
If your trunk is marginal, two smaller branches may distribute better than forcing one large line.
Leak Sealing, Insulation, and Balancing Dampers
Mastic every seam, then tape the jacket.
Use R‑8 in the attic to avoid condensation.
Set the balancing damper so the hot room hits target, then confirm other rooms still meet comfort.
Seal, Insulate, and Prevent Condensation/Mold in South Florida Conditions
Vapor matters: In humid air, cold ducts sweat. Continuous vapor barrier and R‑8 insulation prevent drips and mold.
Boot sealing: Seal the boot‑to‑ceiling gap so the return doesn’t suck attic air and the supply doesn’t dump cool air into the attic.
Dew point awareness: Don’t run uninsulated metal through hot spaces. Any exposed cold metal will sweat.
Keep flex tight: Loose, wrinkled flex increases friction (less CFM) and can create cold spots that sweat.
Noise Control & Airflow Balance (Static Pressure Targets and Quick Tests)
Noise usually means velocity or restriction. Upsize grilles/ducts or reduce sharp turns.
Balance with dampers at takeoffs, not by closing grilles (which can whistle).
Static pressure: Use your manometer to measure TESP at the air handler (supply + return). Compare to the manufacturer’s spec; if you exceed it after your changes, back off and call a pro.
Using a Manometer & Anemometer: Pass/Fail Checks You Can Do
Register CFM: Measure face velocity (fpm) with the anemometer, multiply by grille free area (ft²) to estimate CFM. If you’re not meeting ~300 CFM in the hot room, open the damper or reduce restrictions.
Pressure sanity check: If your TESP rises noticeably after adding ducts or returns, the system is getting more restrictive—stop and reassess.
Costs & Timelines for a 2,700‑Sq‑Ft Wellington Home (DIY vs. Pro Scenarios)

Below is a sample project that adds one new 14–16" return, improves a 300‑sq‑ft hot room with one new 8–10" supply, and seals/insulates critical runs. Prices reflect Palm Beach County retail ranges; your mileage may vary.
Line‑Item Cost Table (Materials; DIY vs. Typical Pro Installed)
Where totals land:
DIY heavy (you do most labor): ~$1,000–$2,400 in materials.
Pro‑installed (typical small‑to‑medium scope): ~$3,000–$6,000 all‑in — right on target with your budget.
Timeline: A focused DIYer can stage and complete this over 1–2 weekends (cool morning hours). A pro crew often completes it in 1 workday if access is good.
Get Help Fast: How to Vet a Licensed HVAC Contractor (Palm Beach County)
Ask for license (CAC#), insurance, and permit handling upfront.
Request Manual J/S/D deliverables or, at minimum, room‑by‑room CFM targets and a balancing plan.
Require before/after static pressure and photos of sealing/insulation.
Prefer larger, quieter grilles and R‑8 attic runs.
“I’m targeting ~300 CFM for a 300‑sq‑ft room and adding a new 14–16" return. Please quote the work with permit, balancing, and TESP verification.”
FAQs: Adding Ductwork to Older Homes & Common Palm Beach Questions
Can I DIY adding a return without resizing the trunk?
Often yes—returns reduce restriction and help balance. Still, check static pressure after; if it spikes or airflow drops elsewhere, call a pro.
What R‑value should I use for attic ducts in South Florida?
R‑8 for supply/return in unconditioned attics is a practical target to minimize sweating and energy loss.
What’s an acceptable static pressure range?
Use the manufacturer’s spec on your air handler. Many systems are designed around ~0.5 in. w.c. TESP; treat that as a reference, not a rule—verify your model.
Flex or metal?
I use metal for plenums, trunks, and takeoffs; flex R‑8 for short, straight branches. Metal is durable and quiet; flex is fast and forgiving if installed tight and well‑supported.
How do I balance airflow to fix a 300‑sq‑ft hot room?
Hit ~300 CFM via larger grille(s) and appropriately sized duct(s), add a return path, then set balancing dampers. Verify with anemometer readings.
Do I need a permit to replace or add ducts?
You may; especially for new runs and plenum changes. Check with Palm Beach County/Wellington before starting.
Conclusion
If you’re reasonably handy and careful, adding/upsizing returns and right‑sizing the hot room supply are solid DIY wins. The keys are planning, sealing/insulating for humidity, and measuring (not guessing). When in doubt—especially if TESP climbs, the trunk needs surgery, or permits feel murky—bring in a licensed pro and have them document CFM targets and static pressure. That’s how you turn a sweltering 300‑sq‑ft room into a calm, quiet space that actually matches the thermostat.